      Home >> Product >> CMTS inverter performance test system

      Detection system

      CMTS inverter performance test system

      Inverter load test system

      An overview.

      At present, many domestic manufacturers of the inverter load testing system mostly adopts the traditional way - - excitation motor commissioning, especially power consumption, and easy to heat damage excitation. With the increasing application of market of the high power converter more widely, there are increasingly high requirements, not only the product function to be rich, but to reliable quality. The inverter power is very sensitive to temperature, especially the inverter module temperature control is one of the most important indexes in the whole frequency stability test, the only means of detecting temperature is corresponding with the rated current of power, has reached the required test. But with the production of power is increased at the same time, the power transformer also increased, which brings a lot of investment to the enterprise, and every year to pay a sum of not a small capacity fees, at least tens of thousands, many hundred thousands of, all the year round utilization rate is not high; so how can not increase power supply capacity and can solve the high power converter debugging problems Many companies are hoping to find a more reasonable economic inverter load test system!

      Here is a inverter load test system, three-phase asynchronous motor load test system uses a common bus and motor - feedback principle, energy saving rate is currently one of the highest load test system (energy saving rate is more than 80%); the load test and inspection is mainly applied to the inverter, but also can provide some data for the inverter manufacturers reference; includes voltage current power temperature, convenient and timely improve the products manufacturers.

      Two. The system performance characteristics

      Load part 1 of this system consists of several groups of three-phase AC asynchronous motor, with the load test of large capacity, convenient installation, power may be increased to hundreds of kilowatts, each power segment covering the basic inverter, due to the adoption of the three-phase asynchronous motor, with high reliability, simple maintenance etc.. The motor has simple installation method (below), motor with two identical power cross docking, formation of drag - feedback self circulation control feedback mode, by changing the slip ratio of the motor to change the magnitude of the load current, full load the test frequency converter working in real.

      Part of the common bus system feedback 2 energy, measured consumes most of the energy converter is composed of feedback (power generation) motor feedback provides good, after the actual test results show that the frequency converter, energy consumption accounted for only actual measured power of 15%--20%, saving rate reached 80%, energy-saving effect is very significant, long-term use, companies can save a substantial amount of electricity; the system not only saves electricity load test, but also greatly reduce the installed capacity of power supply and distribution system (transformers), frequency converter with 380V/315KW testing, as long as the power transformer power transformer configuration 80-100KVA capacity will meet the requirements, enterprises can save a lot of investment; this is not exciting loading system this match.

      3 integration design, test system in the past have feedback unit (compound excitation converter), test system, platform independent display, connect the entire system through a cable, not only a waste of space, but also is not beautiful, I now do the improvement based on the original, the design concept of integration the feedback unit, (compound excitation converter), direct embedding operation in the system cabinet, making the appearance more reasonable, but also improves the stability of the system, reduces the land area of the system.

      low pressure transducer load test scheme, to increase product line left a certain space. In the future, just add some separate auxiliary parts, to complete the product energy consumption test of low voltage inverter.

      Fig. 1 motor docking

      Fig. 2 the appearance of the product graph

      Three, the system configuration

      1 the subjects of inverter

      2 load with negative excitation converter

      3 asynchronous motor generator

      4 measuring unit and the discharge unit

      5 power management system

      Four, investment and economic analysis

      An annual output of 1 tens of millions of enterprises: according to the average 1KW / 200 yuan calculation,

      Power consumption of 1 year =1000 million / 200 yuan =5 million KW, the current 380V electricity is 1 yuan about /1 degrees, so a year of electricity is 50000 yuan, so can save electricity 50000 * 80%=4 million.

      Secondly, the annual savings of transformer loss cost several million (general transformer capacity greater than 150KVA charge loss cost, power is greater the higher the charges, and every place is different), the investment cost plus the transformer itself; the whole year for companies to save the cost of not less than 100000 yuan, has the very good economic benefit.

      Five, function and technique index

      (1) system

      1 system can carry on the full load test, no-load test, temperature test, temperature rise test, overload test on low voltage frequency converter.

      2 system to the three-phase input / detection of the inverter output voltage, current, power, power factor, voltage and other commonly used data.

      3 overvoltage, undervoltage protection, over-current, short phase protection.

      (2) technical indicators:

      1 energy saving target:

      Energy saving 80% to 85%

      2 power range:

      3.7-315KW

      3.7-400KW

      3.7-500KW

      The 3 voltage measurement

      Voltage measurement accuracy: + 0.2%

      Voltage display accuracy: 1 decimal places

      4 current measurement

      Current measurement accuracy: + 0.2%

      Current test range: depends on the current transformer

      The current display accuracy: 1 decimal places

      5 power factor measurement:

      Power factor measurement accuracy: + 0.5%

      Power factor accuracy: 1 decimal places

      Attached: frequency

      Previous:none

      Next:none

      Dedication, innovation, and beyond, and dedication
      Contact us
        Shanghai /ADD Pudong Tang Town Industrial Zone No. 518 spring Ya Lu
        sales@cmega.com.cn
        4006-686-369
        021-51001653
      Address: 518 Chunya Road, Tangzhen Industrial Park, Pudong, Shanghai
      Customer service hotline: 4006-686-369
      Sales switchboard: 021-51001653 501363 50135203 50135303 Fax: 021-51862113
      信息產業部網站備案:滬ICP備12028121號-1 滬公網安備 31011502003759號
      top 主站蜘蛛池模板: 少妇人妻偷人精品视频| 国产成人综合在线观看不卡| 中文字幕无码专区一VA亚洲V专| 亚洲国产日韩a在线亚洲| 亚洲精品在线二区三区| 国产偷窥熟女高潮精品视频| 亚洲av成人午夜福利| 国产精品极品美女免费观看| 免费无码又爽又刺激成人| 欧美日韩精品一区二区视频| 欧美精品日韩精品一卡| 国产在线无码精品无码| 高h喷水荡肉爽文np肉色学男男| 日韩av一区二区三区不卡| 97视频精品全国免费观看| 天堂а√在线中文在线| AVtt手机版天堂网国产| av网站可以直接看的| 无码国产精品一区二区av| av午夜福利一片免费看久久| 国产成人精品久久综合| 特级无码毛片免费视频尤物| 黑巨人与欧美精品一区| 国产精品v片在线观看不卡| 亚洲成av一区二区三区| 精品亚洲成a人在线看片| 欧美变态另类zozo| 九九久久人妻精品一区色| 蜜臀av一区二区精品字幕| 国产成人精品永久免费视频| 亚洲中文字幕无码爆乳APP| 国产乱码精品一区二区三区四川人| 五月婷婷久久中文字幕| 综合亚洲色图| 亚洲综合一区二区三区在线| 国产精品 无码专区| 成年大片免费视频观看| 久久天天躁狠狠躁夜夜2o2o| 欧美亚洲另类自拍偷在线拍| 国产精品午夜av福利| 四虎亚洲国产成人久久精品|